How To Light Pilot On Furnace

How To Light Pilot On Furnace

In case your furnace has a pilot mild, you could have to relight it sometimes. It is a comparatively easy job that you are able to do your self. Nevertheless, it is very important observe the steps rigorously to keep away from any accidents.

Earlier than you begin, be sure that the furnace is turned off. You must also open a window or door to make sure that there may be loads of air flow. Then, find the pilot mild meeting. That is often a small, steel tube with a flame burning inside. There will likely be a knob or lever that you should use to show the fuel on and off.

After getting positioned the pilot mild meeting, it’s good to flip the fuel on. To do that, flip the knob or lever clockwise till you hear a click on. You might also have to press a button to ignite the flame. As soon as the flame is lit, you possibly can regulate the knob or lever to regulate the dimensions of the flame.

Figuring out the Pilot Gentle

Finding the pilot mild in your furnace is important earlier than making an attempt to mild it. Here is an in depth information that will help you establish the pilot mild:

  • Find the Furnace: The furnace is often positioned within the basement, utility room, or attic. It is often a big steel field with pipes and wires hooked up.
  • Entry the Burner Meeting: Open the entry panel or door on the furnace to show the burner meeting. That is the place the pilot mild is often positioned.
  • Establish the Pilot Gentle: The pilot mild is often a small, flame-like burner on the base of the burner meeting. It could be positioned subsequent to a fuel valve or igniter change.
  • Distinguish from Different Flames: When you see a number of flames within the burner meeting, be certain that to establish the right one. The pilot mild is often the smallest and most regular flame.
  • Test for a “P” Marking: Some pilot lights have a “P” image or marking etched on them to assist establish them simply.
Ideas for Figuring out the Pilot Gentle
Search for a small, blue flame.
Test the situation close to a fuel valve or igniter change.
Distinguish from bigger, flickering flames.
Test for a “P” marking on the pilot mild.

Finding the Gasoline Valve

To find the fuel valve to your furnace, observe these steps:

  1. Discover the furnace.
    The furnace is often positioned in a basement, attic, or utility closet. It’s a massive steel field with a blower fan and a burner.
  2. Search for the fuel line.
    The fuel line is a steel pipe that runs to the furnace. Will probably be related to a valve on the aspect of the furnace.
  3. Establish the fuel valve.
    The fuel valve is a small, brass-colored valve that’s positioned on the fuel line. It should have a lever or a deal with that you should use to show it on and off.
Sort of Gasoline Valve Location
Guide Gasoline Valve On the fuel line, close to the furnace
Automated Gasoline Valve Contained in the furnace, close to the burner

Turning Off the Gasoline Provide

Earlier than you start working in your furnace, it is important to show off the fuel provide. This may stop any fuel from leaking out and doubtlessly inflicting a hearth or explosion.

To show off the fuel provide, observe these steps:

  1. Find the fuel valve. It is sometimes positioned close to the furnace or on the fuel line main into the furnace.
  2. Flip the fuel valve to the “off” place. That is often finished by turning the valve clockwise.
  3. Test the fuel line for any leaks. To do that, apply a soapy water resolution to the fuel line. When you see any bubbles forming, there is a leak. Restore the leak earlier than continuing.

As soon as you have turned off the fuel provide, you possibly can safely proceed with lighting the pilot in your furnace.

Gasoline Valve Place Description
Open Permits fuel to move by way of the valve
Closed Prevents fuel from flowing by way of the valve

Lighting the Pilot with a Match

To mild the pilot in your furnace with a match, observe these steps:

  1. Collect your supplies.

    You will want a lighter or match, a long-handled lighter or match holder, and a screwdriver (non-compulsory).

  2. Find the pilot mild meeting.

    The pilot mild meeting is often positioned on the underside of the furnace. It should have a small, spherical window and a fuel valve.

  3. Flip off the fuel provide.

    Find the fuel valve on the fuel line resulting in the furnace. Flip the valve clockwise to show off the fuel provide.

  4. Gentle the pilot mild.

    1. Utilizing a long-handled lighter or match holder, mild a match or lighter.

    2. Maintain the flame close to the pilot mild meeting.

      The pilot mild ought to ignite inside a couple of seconds.

    3. If the pilot mild doesn’t ignite, repeat steps 4a and 4b.

      If the pilot mild nonetheless doesn’t ignite, you could want to make use of a screwdriver to regulate the fuel valve. Flip the valve counterclockwise barely to extend the fuel move.

  5. Activate the fuel provide.

    As soon as the pilot mild is lit, flip the fuel valve counterclockwise to activate the fuel provide.

  6. Regulate the pilot mild flame.

    The pilot mild flame needs to be about 1/2 inch lengthy. If the flame is just too lengthy, it might trigger the furnace to overheat. If the flame is just too brief, it might exit.

  7. Reassemble the furnace.

    As soon as the pilot mild is lit and adjusted, reassemble the furnace by closing the entry panel.

Lighting the Pilot with an Digital Igniter

In case your furnace has an digital igniter, lighting the pilot is a comparatively easy course of. Listed below are the steps it’s good to observe:

1. Flip Off Gasoline Provide

Earlier than you begin, flip off the fuel provide to the furnace. That is often finished by turning a valve positioned on the fuel line.

2. Discover the Pilot Meeting

The pilot meeting is often positioned close to the underside of the furnace. It should have a small, spherical window by way of which you’ll be able to see the pilot flame.

3. Flip the Igniter Change to “On”

Find the igniter change on the furnace. It should often be a small, crimson or black button. Flip the change to the “On” place.

4. Press and Maintain the Reset Button

As soon as the igniter change is turned on, press and maintain the reset button. This button is often positioned close to the igniter change. Maintain the button for about 30 seconds.

5. Observe the Pilot Flame

After about 30 seconds, it’s best to see the pilot flame ignite. If the flame doesn’t ignite, wait a couple of minutes and check out once more. If the flame nonetheless doesn’t ignite, there could also be an issue with the igniter or the fuel provide. Contact a professional technician for help.

As soon as the pilot flame is ignited, launch the reset button. The flame ought to stay lit, and the furnace ought to begin heating.

Here’s a desk summarizing the steps for lighting the pilot with an digital igniter:

Step Motion
1 Flip off fuel provide.
2 Discover the pilot meeting.
3 Flip the igniter change to “On”.
4 Press and maintain the reset button for 30 seconds.
5 Observe the pilot flame.

Adjusting the Pilot Flame

As soon as you have efficiently lit the pilot flame, it is necessary to regulate it for optimum efficiency. Listed below are the steps to take action:

1. Flip On the Gasoline Valve

Find the fuel valve on the furnace and switch it on by turning it counterclockwise. It is best to hear a clicking sound because the fuel flows into the pilot meeting.

2. Gentle the Pilot Flame

Observe the directions within the earlier part to mild the pilot flame utilizing a long-reach lighter or match. Maintain the flame close to the pilot orifice till the burner lights up.

3. Regulate the Pilot Flame

Find the pilot adjustment screw close to the pilot burner. It is sometimes a small screw with a slotted or Phillips head.

4. Use a Screwdriver

Utilizing a screwdriver, gently flip the pilot adjustment screw clockwise or counterclockwise till the pilot flame is roughly 3/4 inches lengthy. That is the optimum flame measurement for many furnaces.

5. Test the Flame Shade

The pilot flame needs to be blue in coloration. A yellow or orange flame signifies incomplete combustion and needs to be adjusted till it burns blue.

6. Observe the Flame Stability

The pilot flame needs to be secure and steady. If it glints or goes out intermittently, it might point out a fuel provide difficulty or different issues with the furnace. On this case, it is best to name a professional technician for inspection and restore.

Pilot Flame Shade Indication
Blue Optimum combustion
Yellow/Orange Incomplete combustion, regulate flame

Relighting a Extinguished Pilot

In case your furnace’s pilot mild has gone out, you possibly can relight it your self by following these steps:

1. Flip off the fuel provide to the furnace.

2. Wait 5 minutes for the fuel to dissipate.

3. Find the pilot mild meeting.

4. Push within the reset button.

5. Maintain down the ignition button and lightweight the pilot mild with a match or lighter.

6. Launch the ignition button and maintain the reset button for 30 seconds.

7. Activate the fuel provide to the furnace.

If the pilot mild stays lit, your furnace is able to use. If the pilot mild goes out once more, there could also be an issue with the furnace that must be repaired by a professional technician.

Doable Causes of Pilot Gentle Extinguishment Options

Clogged or soiled pilot mild orifice

Clear the orifice with a small brush or wire.

Defective thermocouple or thermopile

Substitute the thermocouple or thermopile.

Blocked fuel line

Clear the blockage from the fuel line.

Tips on how to Gentle Pilot on Furnace

1. **Find the pilot mild meeting.** It’s often positioned close to the underside of the furnace.
2. **Flip off the fuel provide to the furnace.** That is often finished by turning a valve positioned close to the fuel meter.
3. **Wait a couple of minutes for the fuel to dissipate.** This may assist to forestall an explosion.
4. **Use a protracted lighter or match to mild the pilot mild.** Maintain the flame close to the pilot mild meeting and activate the fuel provide.
5. **Hold the flame on the pilot mild for about 30 seconds.** This may permit the pilot mild to ignite and keep lit.
6. **Activate the furnace.** The furnace ought to now begin to warmth up.

Troubleshooting Widespread Pilot Gentle Points

8. The pilot mild will not keep lit.

**Doable causes:**

  • The thermocouple is soiled or broken.
  • The fuel provide will not be turned on all the way in which.
  • The pilot mild meeting will not be correctly adjusted.

Options:

  1. Clear or exchange the thermocouple.
  2. Activate the fuel provide all the way in which.
  3. Regulate the pilot mild meeting based on the producer’s directions.

If you’re having hassle lighting the pilot mild in your furnace, it is very important name a professional technician. A technician can diagnose the issue and be sure that your furnace is working safely.

Security Precautions for Lighting a Pilot Gentle

Earlier than making an attempt to mild a pilot mild, make sure you observe these essential security precautions to reduce dangers:

1. Test for Gasoline Leaks

Previous to igniting the pilot mild, examine all fuel traces and connections for any leaks. Use a soapy water resolution and apply it to the suspected areas. Bubbles point out a leak, requiring instant restore by a professional technician.

2. Clear Obstructions

Confirm that the pilot meeting and its environment are free from particles or blockages. Guarantee there’s correct airflow to facilitate ignition.

3. Ventilate the Space

Open home windows and doorways to make sure ample air flow in the course of the lighting course of. This prevents fuel accumulation and potential hazards.

4. Extinguish Flames

Guarantee there are not any open flames or smoking supplies close to the pilot mild space. Exterminate any potential sources of ignition.

5. Apply Warning

By no means try and mild a pilot mild in case you are inexperienced or have any doubts. Search help from a professional technician.

6. Shield Your self

Put on acceptable security gear comparable to gloves and security glasses to guard in opposition to potential sparks or sizzling surfaces.

7. Observe Producer’s Directions

Consult with the producer’s directions for particular procedures on lighting the pilot mild to your explicit furnace mannequin.

8. Use the Appropriate Instruments

Make use of the suitable instruments for igniting the pilot mild, comparable to a long-reach lighter or a spark igniter.

9. Lighting the Pilot Gentle

Observe these detailed steps to securely mild the pilot mild:

  1. Find the fuel management valve and switch it to the “Off” place.
  2. Find the pilot meeting and the ignition button.
  3. Depress the ignition button and maintain it whereas concurrently opening the fuel management valve barely.
  4. Observe the pilot mild by way of the viewing window and make sure if it ignites.
  5. Hold the ignition button depressed for about 30 seconds to permit the thermopile to warmth up.
  6. Launch the ignition button and examine if the pilot mild stays lit.
  7. If the pilot mild extinguishes after releasing the ignition button, rigorously repeat steps 4-6.
  8. If unsuccessful after a number of makes an attempt, contact a professional technician for help.
  9. As soon as the pilot mild is lit, regulate the fuel management valve to the specified flame top.

Keep in mind to observe these security precautions and lighting directions diligently to reduce dangers and make sure the secure and environment friendly operation of your furnace.

Examine and Clear

Usually examine the pilot meeting for any filth, particles, or corrosion. Clear the thermocouple and pilot tube utilizing a mushy brush or compressed air. This helps guarantee correct fuel move and ignition.

Test Gasoline Strain

Utilizing a manometer, measure the fuel strain on the pilot mild. It needs to be throughout the specified vary to your furnace. If the strain is just too low or excessive, regulate it accordingly to make sure optimum flame stability.

Clear Obstructions

Be sure that there are not any obstructions blocking the air consumption or exhaust vents of the furnace. Clear any particles or mud that will hinder correct air circulation and stop the pilot mild from staying lit.

Preserve Correct Airflow

Sufficient airflow is essential for a secure pilot mild. Examine and clear the blower motor and filter to make sure they’re functioning correctly and offering adequate air circulation all through the system.

Tighten Connections

Over time, connections can change into free, inflicting fuel leaks and interfering with the pilot mild. Tighten all fuel line connections, together with these on the pilot meeting, fuel valve, and thermocouple.

Substitute Thermocouple

The thermocouple generates a small electrical present that retains the fuel valve open. If the thermocouple fails, the fuel valve won’t open, and the pilot mild will exit. Substitute the thermocouple if it turns into defective.

Regulate Pilot Flame

The pilot flame needs to be a small, regular blue flame. If the flame is just too massive, it could possibly overheat the thermocouple, inflicting it to fail. If the flame is just too small, it might not generate sufficient present to maintain the fuel valve open. Regulate the pilot flame utilizing the adjustment screw on the fuel valve.

Examine Warmth Exchanger

A cracked or broken warmth exchanger can launch harmful carbon monoxide into the air. Periodically examine the warmth exchanger for any cracks or leaks, and have it repaired or changed if needed.

Use Authorized Gas

Solely use the kind of gas specified within the furnace guide. Utilizing an incompatible gas can injury the pilot meeting and result in combustion issues.

Name a Certified Technician

If you’re uncomfortable performing any of those duties or encounter any difficulties, it’s advisable to contact a professional HVAC technician who can safely and successfully keep your furnace’s pilot mild.

How To Gentle Pilot On Furnace

In case your furnace will not be working, one of many first issues it’s best to examine is the pilot mild. The pilot mild is a small flame that ignites the fuel in your furnace. If the pilot mild will not be lit, your furnace won’t be able to supply warmth.

To mild the pilot mild, you will have a protracted match or a lighter. First, find the pilot mild meeting. It’s often positioned on the backside of the furnace. After getting discovered the pilot mild meeting, flip the fuel valve to the "off" place. This may cease the move of fuel to the pilot mild.

Subsequent, use the lengthy match or lighter to ignite the pilot mild. Maintain the match or lighter as much as the pilot mild and switch the fuel valve to the "on" place. The pilot mild ought to ignite instantly. If it doesn’t ignite, attempt once more.

As soon as the pilot mild is lit, flip the thermostat to the specified temperature. The furnace will now begin to produce warmth.

Folks Additionally Ask

How do I do know if my furnace pilot mild is out?

In case your furnace will not be producing warmth, the pilot mild could also be out. You’ll be able to examine the pilot mild by wanting by way of the sight glass on the furnace. If the pilot mild will not be lit, it should seem darkish.

Why will not my furnace pilot mild keep lit?

There are a couple of explanation why your furnace pilot mild could not keep lit. One motive is that the thermocouple could also be defective. The thermocouple is a tool that senses the presence of the pilot mild and sends a sign to the fuel valve. If the thermocouple is defective, it won’t be able to ship a sign to the fuel valve, and the fuel valve will shut off the move of fuel to the pilot mild.

Another excuse why your furnace pilot mild could not keep lit is that the fuel strain could also be too low. If the fuel strain is just too low, the pilot mild won’t be able to remain lit. You’ll be able to examine the fuel strain through the use of a manometer.

Lastly, your furnace pilot mild could not keep lit if the venturi tube is clogged. The venturi tube is a small tube that mixes air with fuel. If the venturi tube is clogged, the pilot mild won’t be able to get sufficient air to remain lit. You’ll be able to clear the venturi tube through the use of a small brush.